Data Centers & IT Infrastructure

Data Center Cable and Structured Cabling In Stock and Ready to Ship

A Cat 6A plenum cable from Commodity Cables ships with a 35-year structured cabling warranty, backed by joint channel agreements with the connectivity manufacturers who tested it. That warranty covers every shielded and unshielded build in the category cable catalog, from riser cable in the equipment room to outdoor direct burial between campus buildings, all stocked across our 11 locations. For the integrator building out a data center on a commissioning deadline, the warranty matters. Having the full package in stock and shipping same day from one source matters more.

Cable Types We Stock for Data Center Builds

Cable Family What We Stock Common Data Center Use
Cat 6 Riser, plenum, shielded riser, shielded plenum, no-spline, stranded Structured cabling for 1GbE to 10GbE horizontal runs
Cat 6A Riser, plenum, shielded riser, shielded plenum 10GbE and future-proofed backbone and switch links
Cat 5E Riser, plenum, shielded, 25 pair, stranded Legacy infrastructure and voice circuits
Bundled Cable Dual and quad Cat 5E / Cat 6 under one jacket One-pull installs for structured wiring conduit
Coax RG6, RG6 Quad, RG59 in riser and plenum Broadband, CCTV, and surveillance feeds
Outdoor Direct burial and aerial with messenger Campus and entrance facility runs

Riser and Plenum Builds for Every Run in the Building

Riser and plenum sit in the same warehouse under the same ship schedule. Both jacket ratings are stocked across the full Cat 6 and Cat 6A line, including shielded variants, so a split-spec takeoff ships on one PO without backorder holds. Every Cat 6 and Cat 6A SKU ships with a downloadable spec sheet confirming jacket listing, AWG, conductor count, and code compliance. The quote team verifies availability before the PO drops.

Shielded vs Unshielded: What the Spec Calls For

Shielded Cat 6 and Cat 6A (F/UTP and S/FTP) protect against alien crosstalk in high-density switch and server environments where adjacent cable bundles run parallel for long distances. Unshielded (U/UTP) is the standard for most horizontal runs where separation and twist geometry handle the noise rejection internally.

Commodity Cables stocks both, including Shielded Cat 6 Riser 6SHDCMRX, Shielded Cat 6 Plenum 6SHDCMPRX, Shielded Cat 6A Riser 6ASHDCMRXX, and Shielded Cat 6A Plenum 6ASHDCMPRX. When the spec calls for shielded, the warehouse has it.

The 35-Year Structured Cabling Warranty

Cat 6 and Cat 6A cable from Commodity Cables is channel-tested with leading connectivity manufacturers and backed by a 35-year end-to-end structured cabling warranty. The warranty covers UTP and fiber structured cabling installed to TIA/EIA-568-A and ISO/IEC 11801 standards. It does not cover the full product catalog. See the warranty terms for conditions and registration.

Data Center Cable Built Past the Minimum Spec

Data center cable sourcing usually means piecing together three or four suppliers: one for structured cabling, one for the shielded variants, one for the outdoor campus runs, and another for coax. Commodity Cables carries all of it in one catalog, so the submittal package, the cut sheets, and the PO all come from the same source.

  • Cat 6 and Cat 6A tested to 600MHz: Cat 6 and Cat 6A are listed above the 250MHz Category 6 minimum, with cross separator construction for consistent electrical performance and additional headroom on high-bandwidth runs
  • Shielded variants stocked, not special-ordered: F/UTP and S/FTP in riser and plenum, including Shielded Cat 6 Riser 6SHDCMRX, Shielded Cat 6 Plenum 6SHDCMPRX, Shielded Cat 6A Riser 6ASHDCMRXX, and Shielded Cat 6A Plenum 6ASHDCMPRX
  • 9 jacket colors available: blue, black, yellow, pink, white, red, orange, gray, green, and purple for color-coded identification across switch rows and zones
  • TIA 862 building automation compliant: Cat 6 SKUs meet ANSI/TIA 862 for structured cabling in intelligent building systems, not just data networking
  • CPR compliant (EN 50575:2014): Construction Products Regulation compliance for data center builds in jurisdictions that require it
  • Sequential footage markings on every pull box for accurate takeoff verification and waste tracking
  • Indoor and outdoor cable in the same quote: campus builds that need plenum Cat 6A inside and direct burial cable outside do not require a second supplier

Learn more about our warehouse network and shipping.

Data Center Cable FAQs

What cable is used in data centers?

Cat 6 and Cat 6A are the primary structured cabling types in modern data centers, with Cat 6A preferred for 10GbE and higher-density switch links. Both are available in shielded and unshielded, riser and plenum builds. Coax>, bundled cable, and outdoor runs handle surveillance, one-pull installs, and campus entrance facilities.

Can I get cable shipped to a data center build same day?

Yes. In-stock orders placed by 2:30 PM ship the same day from the nearest of our 11 warehouses. The nearest warehouse is selected based on delivery ZIP to keep transit time short. Learn more about our shipping network.

What does the 35-year warranty cover for data center cable?

The 35-year end-to-end structured cabling warranty covers Cat 6, Cat 6A, and bundled Cat 5E / Cat 6 installed to TIA/EIA and ISO/IEC standards and registered before installation. It does not extend to coax, fire alarm, security, or other non-structured-cabling products in the catalog.

One Supplier. Faster Quotes. Fewer Delays.

Questions on a takeoff or a build that needs cable tomorrow? Call 866-945-5051 or get a quote.