Most cable orders in a working plant are not for new construction. A damaged conveyor circuit, failed dock leveler feed, or relocated packing bench often calls for a fast replacement that matches the existing run.
Commodity Cables helps maintenance teams identify the right cable from the jacket markings, confirm the specifications, and order the correct length before the next shift.
We stock VNTC tray cable and aluminum MC for fixed runs, SOOW and SJOOW cord for portable equipment, and Cat 6A for network drops. Downloadable spec sheets make it easier to verify each product before the purchase order goes out.
| Cable Family | What We Stock | Facility Application |
|---|---|---|
| VNTC TC-ER tray cable | 600V copper, PVC insulation with nylon layer, PVC jacket, 3-conductor 14 to 2 AWG and 4-conductor 14 to 6 AWG, bare ground | Fixed power runs between panels and equipment in tray |
| Aluminum MC cable | AA-8030 aluminum conductors, XHHW-2 cores, interlocked aluminum armor, optional PVC jacket | Feeders and branch circuits for added bays and building additions |
| SOOW portable cord | 600V, annealed stranded copper, EPDM insulation, CPE jacket, -40°C to +90°C | Portable and hard-use equipment, replacement tool leads |
| SJOOW portable cord | 300V, same EPDM/CPE construction, -40°C to +90°C | Portable tools and temporary power at the lower voltage rating |
| Cat 6A riser cable | 23 AWG solid bare copper, 4-pair U/UTP, CMR, 10GBASE-T at 500MHz over 100 meters | Network drops for packing benches, scanners, and dispatch stations |
When a fixed run is added or replaced, the order has to match what the tray already carries. VNTC TC-ER tray cable from Commodity Cables is a 600V copper construction with extruded PVC insulation, a nylon layer over each core, and a flame-retardant PVC jacket, built to UL 83 and UL 1277 and rated 90°C wet or dry. Three-conductor builds run 14 AWG through 2 AWG and four-conductor builds run 14 through 6, each with a bare ground sized to the phase conductors. Every reel prints the full marking, TC-ER with THWN-2 cores at 600V, FT4 flame rating, sunlight resistant, direct burial, oil resistant, so a damaged run can be matched to the print on the old jacket before the replacement is ordered.
A new production bay or a warehouse expansion pulls feeder and branch circuits the panel schedule already dictates. Aluminum MC cable carries AA-8030 aluminum conductors under XHHW-2 rated cores with interlocked aluminum armor, 600V at 90°C in wet and dry locations, listed to UL 44 and UL 1569 with ASTM B800, B801, and B836 conductor standards. The conductors are aluminum, not just the armor, so the ampacity table on the spec sheet is the one that governs the pull. The outer PVC jacket is optional and has to be called out on the PO when the installation requires it.
The cords that fail in a plant are the ones that move every day. is rated 600V and SJOOW cord
Every layout change drags its network drops with it. Packing benches, scanner stations, and dispatch workstations land where the workflow needs them, and the cable has to match the route, not just the speed. Cat 6A riser cable 6ACMR234Rx is 23 AWG solid bare copper, four-pair U/UTP, tested to ANSI/TIA 568-C.2 for 10GBASE-T at 500MHz over 100 meters, shipped on 1,000-foot wood reels. Riser construction serves the indoor fixed runs. Where a route crosses a plenum space or leaves the building, the plenum and outdoor Cat 6A constructions carry their own listings, and the 35-year structured cabling warranty applies to eligible category cable builds.
Maintenance orders rarely arrive as a clean material list. Sometimes the starting point is a damaged jacket marking, an equipment nameplate, or the specifications from an existing run. Commodity Cables LLC helps confirm the required construction and organize the order before the PO is submitted.
Yes. Plant maintenance and warehouse fit-out orders pull all of those families under one purchase order, VNTC tray cable for the fixed runs, aluminum MC for added circuits, SOOW and SJOOW for portable equipment, and Cat 6A for the network drops, shipped from the same warehouse inventory on the same schedule.
The cord type letter, voltage rating, AWG, conductor count, and length. SOOW is rated 600V and SJOOW is rated 300V, both built on annealed stranded copper with EPDM insulation and a CPE jacket rated -40°C to +90°C, so the nameplate voltage is what separates them. The spec sheet confirms diameter and weight before the order goes out.
No. The documented riser build, 6ACMR234Rx, is CMR listed for indoor fixed runs, including riser shafts. Plenum spaces call for the CMP construction, routes leaving the building call for the outdoor-rated builds, and high-interference areas have shielded F/UTP options. The route determines the jacket; the speed requirement determines the category.
Need cable matched for a plant maintenance order or a warehouse fit-out? Call 866-945-5051 or get a quote. Stocked orders placed by 2:30 PM ship the same day.