Get the fire alarm cable the job calls for, with the rating, wire size, and shielding checked before you order. Commodity Cables LLC supplies FPLP plenum and FPLR riser cable in shielded and unshielded options for distributors serving fire alarm installation contractors.
Our range includes 14, 16, 18, and 22 AWG sizes across the available products. As your fire alarm cable supplier, we provide downloadable product information so you can compare the details and confirm the right part number for the job.
Request Fire Alarm Cable Pricing
Start with the required cable rating, then match the wire size, number of conductors, and shielding. FPLP identifies plenum-rated fire alarm cable for qualifying air-handling spaces. FPLR identifies riser-rated fire alarm cable for qualifying vertical runs between floors.
| Cable Option | Example Part Number | Size | What It Provides |
|---|---|---|---|
| FPLP unshielded | FPLP182URR | 18 AWG, 2 conductors | Solid copper, plenum-rated cable without a foil shield |
| FPLP shielded | FPLP162SRR | 16 AWG, 2 conductors | Solid copper, plenum-rated cable with foil shielding and a drain wire |
| FPLR unshielded | FPLR182URR | 18 AWG, 2 conductors | Solid copper, riser-rated cable without a foil shield |
| FPLR shielded | FPLR182SRR | 18 AWG, 2 conductors | Solid copper, riser-rated cable with foil shielding and a drain wire |
These are selected options, not the full range. Review the fire alarm cable spec sheet for construction details and check current availability before placing the order.
The route through the building helps determine which cable rating the job needs. A cable used in an air-handling space has different requirements from one used in a riser between floors. Follow the approved project requirements and applicable code rather than choosing by jacket color or wire size alone.
The rating also does not settle every other choice. A label such as 18/2 means 18 AWG wire with two conductors, while 14/4 means 14 AWG wire with four conductors. Our product documents list several sizes and conductor counts, so match the complete part number to the circuit and equipment instructions before ordering.
Choose shielding based on the fire alarm equipment instructions and the job requirements, not as an automatic upgrade. Our shielded fire alarm cable uses aluminum foil and a tinned copper drain wire. Unshielded versions do not have that foil layer.
Our shielded and unshielded fire alarm cables use solid bare copper conductors. If you are quoting a replacement or an alternative product, compare the full requirements rather than matching only the gauge. That includes the cable rating, conductor count, shielding, and any installation instructions from the equipment manufacturer.
Our downloadable documents give distributor teams the information they need to check an order before it reaches the installation crew. The copper line card lists fire alarm products alongside the rest of our copper range, while the dedicated fire alarm sheet provides construction and cable-marking details.
Commodity Cables LLC has 11 warehouse locations across the United States. For in-stock orders, ask our team to confirm same-day shipping eligibility and the shipping location for your delivery address. If the job also includes alarms or access control, explore our security-system cable range to review related options.
Send the details needed to match the product and check availability:
If you are comparing an alternative to a specified product, include the original product sheet. That gives our team a clear starting point for checking the requested cable rather than guessing from a short description.
Selected products are listed in 500-foot boxes or reels, while others are listed in 1,000-foot packages. Packaging varies by part number, so confirm the required length and package type when requesting a quote.
Yes. Our copper and low-voltage range includes fire alarm, security, control, coax, speaker, and thermostat cable. Distributors can combine those needs in one order, with current stock and shipping details confirmed for the requested products.
No. The 35-year structured cabling warranty does not extend to fire alarm cable. It applies to eligible registered UTP and fiber structured cabling installations under the published warranty terms.
Send us the cable requirements and delivery details, and we will help confirm the part number, current stock, and shipping options. Request a fire alarm cable quote or call 866-945-5051. Browse our copper and low-voltage cable range if the order includes other wiring for the same project.